Refrigeration Units & Systems

At Reefer Zone we do not use one standard refrigeration unit for every application. We select and design each system around the required temperature, cooling load, facility size, product, operating conditions and pattern of use.

Operating range
+10 → −40°C
Temperature categories
3
For deep freezing
Two-Stage
System selection steps
7

Refrigeration engineered for each application

We offer a complete range of condensing units and refrigeration systems covering chilling, freezing and deep-freezing applications. Compressors, components, evaporators and controls are selected to deliver the required performance, reliability and operating efficiency.

CategoryDescriptionApplicationsCompressors and range
Positive Temperature RefrigerationKeeps products that need low temperatures without freezing, preserving their quality and reducing losses during storage and handling.Fresh-produce holding and storage rooms · Fresh fruit and vegetables · Dairy products · Fresh meat and poultry · Food and beverages · Some pharmaceutical and medical applicationsHermetic or Semi-Hermetic — range 0 to +10°C
Low Temperature & Freezing RefrigerationDesigned for applications that need low temperatures to keep products frozen or to freeze them, allowing for continuous operation and the heat that must be drawn out of products and refrigerated spaces.Frozen product stores · Meat, poultry and fish freezing rooms · Frozen food stores · Holding rooms for products after freezingSemi-Hermetic and Hermetic
Deep Freezing & Ultra-Low TemperatureWhen a process needs very low evaporating temperatures, system engineering and the choice of compressor and components matter even more. Reefer Zone supplies solutions for ultra-low temperature applications, including Two-Stage systems designed for high compression ratios and low evaporating temperatures.Blast freezing tunnels · Ultra-low temperature storage rooms · Applications with operating temperatures down to −40°C or below, depending on system designTwo-Stage

Low-noise units (Silent / Ultra Quiet)

We also offer low-noise refrigeration units that combine reliable cooling performance with a compact design. They suit applications that need low noise levels, such as shops, restaurants, pharmacies and sites close to residential areas.

  • Ultra Quiet: quieter operation than conventional units.
  • Compact Design: a compact build, wall-mountable in some applications.
  • Flexible Installation: suited to sites that need to limit noise and preserve the look of the space.

Evaporator Coils

The evaporator is a core part of any refrigeration system: its design directly affects air distribution, how quickly the required temperature is reached and how stable storage conditions remain. Reefer Zone offers a range of evaporator and coil designs to suit the room dimensions, temperature, product and air-distribution requirements.

  • Cubic Evaporators — for applications that need air directed mainly in one direction; selected according to the room dimensions and the evaporator’s position.
  • Double Throw — distributes air in two directions, for a more balanced spread in rooms that need wider air coverage.
  • Dual Throw — gives more flexibility in air distribution inside chillers and freezers; the throw directions are chosen according to the room dimensions and the evaporator’s position.

Mechanical, electrical and lighting works

We carry out the complete mechanical and electrical works for refrigeration systems to industry standards and approved engineering practice: copper refrigerant lines, thermal insulation, the main refrigeration-circuit connections and components, and pressure and vacuum tests before start-up. Electrical works cover control, protection and operating panels, phase and voltage monitoring, temperature controllers, and compressor and fan protection and control, together with interior LED lighting suited to chillers and freezers and resistant to moisture, dust and low temperatures.

Choosing the right system — Engineered for the Application

A refrigeration system is not chosen on nominal capacity alone. It starts with a study of the required temperature, cooling load, use, operating conditions and air distribution, followed by the selection of the right components, from the compressor and condensing unit to the evaporator and controls. Reefer Zone follows an engineering method that runs Application → Temperature → Cooling Load → Compressor → Condensing Unit → Evaporator → Control System to arrive at a complete system matched to each application, balancing performance, efficiency, reliability and running costs.

Reefer Zone delivers complete solutions for chilling and freezing projects, cold stores, freezing tunnels and industrial applications, from condensing units, compressors and evaporators to control systems, so that every project gets the right engineering solution.

A system engineered around the application

Nominal capacity alone does not determine the refrigeration system. Our approach starts with the application and ends with controls, balancing performance, efficiency and operating costs.

  1. Application
  2. Temperature
  3. Cooling Load
  4. Compressor
  5. Condensing Unit
  6. Evaporator
  7. Control System

The right system for every temperature

Three operating categories, with compressors and evaporators selected for the cooling load and product.

Positive temperature refrigeration

0 → +10°C
  • Fruit and vegetables
  • Dairy products
  • Fresh meat and poultry
  • Food and beverages
  • Pharmaceutical applications

Low temperature refrigeration and freezing

  • Frozen product stores
  • Meat, poultry and fish freezing
  • Storage after freezing

Deep freezing

→ −40°C
  • Blast freezing tunnels
  • Ultra-low temperature rooms
  • Two-Stage systems